Key Specifications
IMPENDANCDE
100 OhmHAZARD LEVEL
M (extra low temperature, extra oil and extra fuel resistant)TEMPERATURE RANGE
- 50 to +90°CMinimum bending radius
fixed: 6 x cable diasporadic: movement 10 x cable dia
Category
Features
01
General Properties
Halogen free electron- beam cross linked cables with improved behaviour in case of fire, easy to strip, soldering iron resistant and flexible. Meet the requirements of EN 50288- 2- 2 and IEC 61156- 6.
- Characteristic Impedance: f = 100MHz, 100 + 5 Ω
- Resistance unbalance at 20 °C: ≤ 1.1 Ω / km
- Capacitance:
core / core < 56 pF / m
core / screen ≤ 100 pF / m - Voltage rating: 300 VAC
- Test voltage, 50 Hz, 5 min.: 2000 VAC
- Screening attenuation 30 MHz ≤ f ≤ 100 MHz, 40 dB
- Transfer impedance: f ≤ 30 MHz, 200 mΩ/m
- Temperature range:
fixed - 50 + 90°C
sporadic movement - 40 + 90 °C - Min. bending radius:
Fixed 6 x cable dia
sporadic movement 10 x cable dia (12568935 / 84142178 / 85086347)
02
APPLICATION
The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service. (see table) Guidelines for selection and installation are described in the standard EN 50343.
Standard
In conformity with | Standard | |
---|---|---|
Fire protection on railway vehicles, hazard level | HL1 - HL3 | EN 45545 |
Vertical flame spread Vertical flame spread, bunched, 6 < D < 12 mm Smoke density Corrosivity of combustion gases Amount of halogen acid gas Content of fluorine Toxicity |
50 T ≥ 70 % pH ≥ 4.3, C ≤ 10 µS/mm HCI+HBr ≤ 0.5% HF ≤ 0.1% ITC ≤ 6 |
EN 60332- 1- 2 EN 60332- 3- 25 EN 61034- 2 EN 60754- 2 EN 60754- 1 EN 60684- 2, 45.2 EN 50305, 9.2 |
Fire protection on railway vehicles | Fulfilled | NFPA 130 |
Vertical flame spread Vertical flame spread, bunched Smoke density |
L ≤ 1.5 m TSR ≤ 150 m2, PSRR ≤ 0.40 m2/s |
UL 1685, 12 (FT4 exp.) UL 1685, 12 (FT4 exp.) |
Requirement of hazard level code M: | (according to EN 50264-1 or EN 50306-1) | |
Extra low temperature Extra oil resistance Extra fuel resistance |
- 40°C IRM 902, 72h, 100°C IRM 903, 168h, 70°C |